# AI Edge Gateway (indoor version) activation and connection

Insert the SIM card to be used into the back of the AI Edge Gateway. **NOTE**

Insert the SIM card so that its contacts are on the bottom.

  **WARNING**

Use of a SIM size conversion adapter is deprecated as it may cause damage to the SIM slot.

![](https://manual.amnimo.com/wp-content/uploads/2024/07/画像1-4-1024x513.png)

   Connect the LAN0 port of the AI Edge Gateway to the PC using a LAN cable.

![](https://manual.amnimo.com/wp-content/uploads/2024/07/画像3-2-1024x572.png)

  Set the configuration DIP switch on the front of the AI Edge Gateway to Linux boot mode.

![](https://manual.amnimo.com/wp-content/uploads/2024/07/画像4-1024x575.png)

DIP Switch Icon Description

| DIP Switch | Description. |
| --- | --- |
| ![](https://manual.amnimo.com/wp-content/uploads/2024/07/image-246.png) | ON state |
| ![](https://manual.amnimo.com/wp-content/uploads/2024/07/image-247.png) | OFF state |

 **NOTE**

No. 4 DIP switch can be either ON or OFF. It is not referenced by the boot loader (used only on the application side).

   Connect the AC adapter to the AI Edge Gateway.

Power is automatically turned on and the AI Edge Gateway is activated.

 **  AI エッジゲートウェイ（屋内版）をシャットダウンするには**

Shutdown can be accomplished in one of the following ways During shutdown, the LED PWR will flash; when the LED PWR turns red, the shutdown is complete.

- While the equipment is operating (the startup process is finished and the equipment is fully up), turn off the power by pushing in the PUSH switch on the main unit with a thin object with a sharp tip for at least 3 seconds.

![](https://manual.amnimo.com/wp-content/uploads/2024/07/画像5.png)

- Shut down with the following command

- Refer to the [Edge Gateway Series CLI User's Manual](https://amnimo.com/manual/edge_gw/cli/ja/cli_users_manual.pdf) for command usage.

admin@amnimo:~$ sudo systemctl poweroff
[sudo] password for admin: ← Enter root password and Enter
 Stopping Docomo of user admin.
 Stopping Unpack initramfs on shutdown...
 (Omitted)
 Starting Power-Off
NOTICE: You can turn off the power.

LED indication during shutdown process

| (data) item | PWR | ANT | MOB | ST1 | ST2 | ST3 | remarks |
| --- | --- | --- | --- | --- | --- | --- | --- |
| shutdown process in progress | ![](https://manual.amnimo.com/wp-content/uploads/2024/07/image-248.png) |  |  |  |  |  | 500ms interval |
| power disconnected (state) | ![](https://manual.amnimo.com/wp-content/uploads/2024/07/image-249.png) |  |  |  |  |  |  |

 ****自動起動機能に関する注意事項****

- AI Edge Gateways are designed to operate 24 hours a day, so they have the ability to automatically recover from a shutdown in the event of a failure.
- Therefore, if the AI Edge Gateway is shut down in the manner described in this section, but power is still supplied by the power connector, it will restart.
- If you wish to put the AI Edge Gateway in a power-off state, shut it down and wait until the LED is in a power-off ready state (power LED lit red) before pulling the power plug.