Configure simple settings

Table of Contents

The following settings can be made on the “Simple Settings” screen.

  • Mobile Communication Settings
  • Interface Settings
  • Package Repository Credentials
  • Enable/Disable DNS
  • filter (esp. camera)
  • Enable/Disable DMS (Device Management System)
  • Enable/Disable Nx Witness
NOTE
  • This page is common to AG, AR, and AX series.
  • If you use AR10-000JP (without communication module) model with IoT router, you do not need to set up mobile communication.

Note that the DNS and filtering settings are automatically applied when the simple settings are made. The DNS and filtering settings that are automatically applied are as follows

For detailed settings, please refer to the following manuals.

Feature(data) itemset value (e.g. of a function, parameter, etc.)
Domain Name Systemenable/disable settingvalidity
Filtering input settingsInput Default Policy
related
established
invalid
input interface
discard
permit
permit
discard
permit
Filtering forwarding settingsTransfer Default Policypermit
Filtering output settingsOutput Default Policypermit

NOTE

If your Edge Gateway version is V1.1.2 or earlier, the default DNS server settings are invalid. Also, there is no GUI function.
Updating from V1.1.2 to V1.2.1 or later will disable DNS if it has not been configured. Also, GUI will be disabled.
For information on how to check the version, please refer to the following manual

 

Simple Setup Procedure #

Click on “Simple Settings” on the side menu.

The “Simple Settings” screen appears.

If you are using a mobile connection, select a registered carrier or subscription plan from “Carrier / Subscription Plan” in the Mobile Communications Settings.

The “APN Name”, “Account”, “Password”, and “Authentication Method” will be automatically set according to the selected carrier or subscription plan.

NOTE
  • If the carrier/contract plan to be used is not registered in “Carrier/Contract Plan”, select [Other].
  • When using a SIM that does not require authentication, uncheck both “PAP” and “CHAP” in “Authentication Method”.
  • Steps 1 and 2 are not required for the AR10-000JP (without communication module) model.
WARNING

Incorrectly configured mobile settings may cause the compact router to reboot due to the failsafe feature.

  • When setting up, be sure to set the correct user name and password.
  • If the compact router repeatedly reboots, see the following page.
NOTE

Mobile connection settings are also explained in a video on the following page.

Configure the interface settings according to the environment.
NOTE

Each device has a different interface name. When configuring the settings, please read each name differently.

Click the toggle to enable or disable.
Also check “Dynamic SNAT” if necessary.

Click the toggle to enable or disable.
Select “DHCP Client” or “Fixed IP Address” as the method for assigning “IP Address”. If you select “Fixed IP Address”, you must enter the “IP Address” and “Netmask”.
Also check “Dynamic SNAT” if necessary.

Click the toggle to enable or disable.
Select “DHCP Client” or “Fixed IP Address” as the method for assigning “IP Address”. If you select “Fixed IP Address”, you must enter the “IP Address” and “Netmask”.
Also check “Dynamic SNAT” if necessary.

Enter “User Name” and “Password” as credentials for the package repository.
NOTE

Package repository credentials should only be set if a firmware update is required. Please contact our support for authentication information (user name and password).

DMS Settings. Slide the toggle to enable or disable DMS.
Configure Nx Witness settings. Slide the toggle to enable or disable Nx Witness.
NOTE

If Nx Witness is set to enabled, set the “port number” and “password” as needed.

Scroll to the bottom of the screen and click Settings.

A confirmation screen for the settings will appear.

[Click Settings.

Settings are saved.

Click [Operational Information] – [Mobile Communications] on the side menu to check the status of mobile communications.
Communication module statusmeaning
dialingin the process of connecting
connectedstate of connectivity
disconnecteddisconnected state
WARNING

If the connection is not correct, such as if there is an error in the mobile settings, the device may automatically reboot due to the fail-safe feature. Please be aware of this.

GUIのプロトコルとポート番号を変更するには

Select [Advanced/Control] – [GUI Settings] from the GUI side menu to change the protocol and port number used in the GUI settings.