The following settings can be made on the “Simple Settings” screen.
- Mobile Communication Settings
- Interface Settings
- Package Repository Credentials
- Enable/Disable DNS
- filter (esp. camera)
- Enable/Disable DMS (Device Management System)
- Enable/Disable Nx Witness
- This page is common to AG, AR, and AX series.
- If you use AR10-000JP (without communication module) model with IoT router, you do not need to set up mobile communication.
Note that the DNS and filtering settings are automatically applied when the simple settings are made. The DNS and filtering settings that are automatically applied are as follows
For detailed settings, please refer to the following manuals.
- Configuring Filter Settings ” and ” Configuring DNS Settings ” in the Edge Gateway Series GUI User’s Manual.
Feature | (data) item | set value (e.g. of a function, parameter, etc.) |
---|---|---|
Domain Name System | enable/disable setting | validity |
Filtering input settings | Input default policy related established invalid input interface | 破棄 許可 許可 破棄 許可 |
Filtering forwarding settings | Transfer Default Policy | permit |
Filtering output settings | Output Default Policy | permit |
If your Edge Gateway version is V1.1.2 or earlier, the default DNS server settings are invalid. Also, there is no GUI function.
If you update from V1.1.2 to V1.2.1 or later, DNS will be disabled if it has not been configured. Also, GUI will be disabled.
Please refer to the following manual on how to check the version.
Simple Setup Procedure #
When configuring mobile communication settings on the “Simple Settings” screen, the SIM must be set to slot0.
Please note that if the SIM is not properly set to slot0, or if it is set to slot1, the terminal will restart due to the failsafe function.
The “Simple Settings” screen appears.
The “APN Name”, “Account”, “Password”, and “Authentication Method” will be automatically set according to the selected carrier or subscription plan.
- If the carrier/contract plan to be used is not registered in “Carrier/Contract Plan”, select [Other].
- When using a SIM that does not require authentication, uncheck both “PAP” and “CHAP” in “Authentication Method”.
- Steps 1 and 2 are not required for the AR10-000JP (without communication module) model.
Incorrectly configured mobile settings may cause the compact router to reboot due to the failsafe feature.
- When setting up, be sure to set the correct user name and password.
- If the compact router repeatedly reboots, see the following page.
Mobile connection settings are also explained in a video on the following page.
Each device has a different interface name. When configuring the settings, please read each name differently.
❶ Configure the “ecm0” setting required for mobile connection.
Click the toggle to enable or disable.
Also check “Dynamic SNAT” if necessary.
❷ Configure the “eth0” setting required for WAN connection.
トグルをクリックして、有効または無効に設定します。
「IPアドレス」を割り当てる方法として、「DHCPクライアント」または「固定IPアドレス」を選択します。「固定IPアドレス」を選択した場合は、「IPアドレス」と「ネットマスク」を入力する必要があります。
また、必要に応じて、「ダイナミックSNAT」にチェックを付けます。
❸ Configure the “br0” or “eth1” settings required for LAN connections.
トグルをクリックして、有効または無効に設定します。
「IPアドレス」を割り当てる方法として、「DHCPクライアント」または「固定IPアドレス」を選択します。「固定IPアドレス」を選択した場合は、「IPアドレス」と「ネットマスク」を入力する必要があります。
また、必要に応じて、「ダイナミックSNAT」にチェックを付けます。
Package repository credentials should only be set if a firmware update is required. Please contact our support for authentication information (user name and password).
If Nx Witness is set to enabled, set the “port number” and “password” as needed.
A confirmation screen for the settings will appear.
Settings are saved.
Communication module status | meaning |
---|---|
dialing | in the process of connecting |
connected | state of connectivity |
disconnected | disconnected state |
If the connection is not correct, such as if there is an error in the mobile settings, the device may automatically reboot due to the fail-safe feature. Please be aware of this.
Select [Advanced/Control] – [GUI Settings] from the GUI side menu to change the protocol and port number used in the GUI settings.
- For details, please refer to the GUI User’s Manual.