Overview of simple settings #

The following settings can be made in the “Simple Settings” screen.

  • Mobile Communication Settings
  • Interface Settings
  • Package Repository Credentials
  • Enable / Disable DNS
  • filter (esp. camera)
  • Enable / Disable DMS (Device Management System)
  • Enable / Disable Nx Witness

INFOMATION

Note that the DNS and filtering settings are automatically applied when the simple settings are made. The DNS and filtering settings that are automatically applied are as follows

Feature(data) itemset value (e.g. of a function, parameter, etc.)
Domain Name Systemenable/disable settingvalidity
Filtering input settingsInput default policy
related
established
invalid
input interface
Discard
Permit
Permit
Discard
Permit
Filtering forwarding settingsTransfer Default Policypermit
Filtering output settingsTransfer Default Policypermit

For detailed settings, please refer to the following manuals.
⇒ Edge Gateway Series GUI User’s Manual “Configuring Filter Settings” “Configuring DNS Settings

 

Simple Setup Procedure #

WARNING

When configuring mobile communication settings on the “Simple Settings” screen, the SIM must be set to slot0.
Please note that if the SIM is not properly set to slot0 or set to slot1, the device will reboot due to the failsafe function.

The following is an example of operating the indoor version of the Edge Gateway (AG10).

When the password has been set for the first login, you will be given the option to move to the “Quick Setup” screen or skip it.
[Clicking on the “Skip” button will take you to the “Quick Setup” screen.

Simple Settings” screen

If you are using a mobile connection, select a registered carrier or subscription plan from “Carrier / Subscription Plan” under Mobile Communications, and click [Next].
If you do not need to set up a mobile connection, click “Next” and proceed to the interface settings.

The “APN Name”, “Account”, “Password”, and “Authentication Method” will be automatically set according to the selected carrier or subscription plan.

NOTE
  • If no carrier or subscription plan is registered in the “Carrier / Subscription Plan” field, select “Other”.
  • If you are using a SIM that does not require authentication, uncheck both “PAP” and “CHAP” in “Authentication Method”.

WARNING

Incorrectly configured mobile settings may cause the device to reboot due to the failsafe feature.

  • When setting up, be sure to set the correct user name and password.
  • If the Compact Router repeatedly reboots, please refer to the following page.
    ⇒ Edge Gateway Startup Guide , “Device Repeatedly Reboots”.

NOTE

The mobile connection settings are also explained in the video on the following page.
⇒ ” Connecting your Amnemo device to the Internet

Configure the interface settings according to your environment and click Next.
NOTE

Each device has a different interface name. When configuring the settings, please read each name differently.

Click the toggle to enable/disable.
If you have not set up mobile communication, please set it to [Disabled].
Also check “Dynamic SNAT” if necessary.

Click the toggle to enable/disable.
Select “DHCP Client” or “Static IP Address” as the method for assigning the “IP Address”. If you select “Fixed IP Address”, you will need to enter the IP Address and Netmask.
If necessary, check the “Dynamic SNAT” checkbox.

Click the toggle to enable/disable.
Select “DHCP Client” or “Static IP Address” as the method for assigning the IP address. If you select “Fixed IP Address”, you will need to enter the IP Address and Netmask.
If necessary, check the “Dynamic SNAT” checkbox.

Enter “User Name” and “Password” as credentials for the package repository.If you want to set the package repository credentials later, you can leave it blank.
NOTE

Package repository credentials should only be set if a firmware update is required. If you would like to obtain authentication information (user name and password), please contact our support.

DMS Settings. Slide the toggle to set DMS to Enable/Disable.
Configure Nx Witness settings. Slide the toggle to enable/disable Nx Witness.
NOTE
  • If Nx Witness is enabled, set the “port number” and “password” as necessary.
  • The IoT Router (AR) does not display the Nx Witness item.

[Click Next.
Confirm the information entered and click “Setup”.
Returns to the settings screen.

設定の保存

After completing this setup, please save the settings to make them permanent. You can save the settings by clicking on the link at the top of the screen.

Click [Network] > [Mobile Communications] in the side menu to check the status of your mobile communications.

Communication module statusmeaning
DIALINGin the process of connecting
CONNECTED.state of connectivity
DISCONNECTED.disconnected state
WARNING

If the connection is not correct, such as if there is an error in the mobile settings, the device may automatically reboot due to the fail-safe feature. Please be aware of this.

GUI のプロトコルとポート番号を変更するには

The protocol and port number used in the GUI settings can be changed by selecting [Advanced/Control] > [GUI Settings] from the GUI side menu.

For details, please refer to the following
⇒ For more information, see “Configuring GUI Settings”.