Installation Precautions

Incorrect installation or usage may cause malfunctions or accidents. Please read the following precautions carefully before installation.

  • Do not remove the vent filter for internal pressure adjustment that is affixed to the back of the product. (If you peel it off, you will lose the dustproof and waterproof resistance.)
  • This product is a permanently connected device. If power is to be disconnected, use a power disconnect device outside the equipment.
  • Do not use the product except with a power supply of 100 VAC or 200 VAC. Doing so may cause fire or electric shock.
  • The AC power cable is an optional item and must be connected by the customer at the time of use.
  • For flame resistance of the cable, UL94-V1 or UL94-V0 or higher and flame retardant grade CMX or higher are recommended.
  • For materials used during installation, use our recommended materials or use materials that meet waterproof specification requirements (IP65, IP66).
  • The dustproof and waterproof rating of this product conforms to IP65 for AR20/AG20 and IP66 for AC25. Please note the following when installing the product.
注意

When using our recommended waterproof cable gland, observe the specified tightening torque for the connector during installation. The tightening torque for the screws on the front door of AC25 should be 1.2 N・m. Insufficient installation may cause water infiltration, resulting in failure.