Insert the SIM card so that its contacts are at the back.
Use of a SIM size conversion adapter is deprecated as it may cause damage to the SIM slot.


| DIP Switch | Description. |
|---|---|
![]() | ON state |
![]() | OFF state |
No. 4 DIP switch can be either ON or OFF. It is not referenced by the boot loader (used only on the application side).
Turn on the power switch to activate the edge gateway.
- For details, please refer to the " Outdoor Type Installation Guide " included with the product.

Shutdown can be accomplished in one of the following ways During shutdown, the LED PWR will flash; when the LED PWR turns red, the shutdown is complete.
- While the equipment is operating (the startup process is finished and the equipment is fully up), turn off the power by pushing in the PUSH switch on the main unit with a thin object with a sharp tip for at least 3 seconds.

- Shut down with the following command
- Refer to the Edge Gateway Series CLI User's Manual for command usage.
admin@amnimo:~$ sudo systemctl poweroff
[sudo] password for admin: ← Enter root password and Enter
Stopping Docomo of user admin.
Stopping Unpack initramfs on shutdown...
(Omitted)
Starting Power-Off
NOTICE: You can turn off the power.
LED indication during shutdown process
| (data) item | PWR | ANT | MOB | ST1 | ST2 | ST3 | remarks |
|---|---|---|---|---|---|---|---|
| shutdown process in progress | 500ms interval | ||||||
| power disconnected (state) |
- Since the Edge Gateway is intended to operate 24 hours a day, it has the ability to automatically recover in the event of a shutdown, such as in the event of a failure.
- Therefore, if the Edge Gateway is shut down in the manner described in this section, but power is still supplied by the power connector, it will restart.
- If you want to put the Edge Gateway in a power-off state, shut it down and wait until the LED is in a power-off ready state (power LED lit red) before pulling out the power plug.